Power, cooling and the room that holds them
Eleven product lines across five families — sized together, tested together and delivered from one factory. Every system is configurable to your rack density, redundancy target and site conditions.
- 1 – 800 kVA UPS
- 25 – 120 kW cooling
- 1 – 12 rack pods
- 0.3 – 1.2 MW containers
Flagship
HatchPower HP33 Modular UPS
A hot-swappable modular UPS platform that grows in 50 kVA steps, keeps critical loads on double conversion at 97.6% efficiency and allows zero-downtime maintenance from the front of the cabinet.
HatchPower HP11 Tower UPS
A compact tower UPS for small server rooms, branch offices and telecom cabinets. Online double conversion in a 2U–4U footprint with a maintenance bypass built in.
HatchPower HP33-L Lithium UPS
The HP33 platform paired with LFP battery cabinets and an integrated BMS. Same 97.6% efficiency, but a footprint and weight that fit a retrofit where lead-acid never could.
Flagship
AquaRow IRC In-row DX Cooling
Row-mounted DX units that sit inside the aisle they cool, delivering 25–60 kW of sensible capacity with EC compressors, variable-speed fans and optional free cooling.
AquaRow CW In-row Chilled Water
A chilled-water in-row unit for facilities that already run a central chiller plant. 35–120 kW of sensible capacity in a 300 mm frame, with EC fans and condensate-free operation.
Flagship
MicroCube M1 Single-rack Data Center
Rack, UPS, cooling, PDU, monitoring and fire suppression integrated into a single 42U closed cabinet. Ships assembled, commissioned in a day, expands rack by rack.
MicroCube MD Modular Data Center
A row of 4 to 12 racks with in-row cooling, modular UPS and containment, delivered as a pre-engineered pod and commissioned in two weeks.
CubeDC 20 ft IT Pod
A factory-built 20 ft IT container with 8–12 racks, in-row cooling, UPS and fire suppression. ISO footprint, standard twist locks, shipped anywhere.
CubeDC 40 ft Modular Data Center
A 40 ft container with 20–24 racks, aisle containment and up to 1.2 MW of IT capacity — the building block for multi-megawatt container campuses.
Flagship
LiquidCube CDU Container
A 20 ft container housing N+1 CDUs, primary/secondary loops, filtration and leak detection — the heat-rejection backbone for direct-to-chip liquid cooling.
LiquidCube IM Immersion Tank
A sealed single-phase immersion tank with integrated coolant circulation, heat exchanger and monitoring — the lowest-PUE way to cool a dense rack.
Specification support
Send us the load profile.
Rack count, kW per rack, redundancy and site conditions are enough to start. We return a sized configuration and budgetary price.
