In-row & Precision Cooling
AquaRow CW In-row Chilled Water
Central plant efficiency, row-level control.
A chilled-water in-row unit for facilities that already run a central chiller plant. 35–120 kW of sensible capacity in a 300 mm frame, with EC fans and condensate-free operation.
Overview
Why this system exists
Where a chiller plant already exists, extending it into the row is the lowest-carbon option. The AquaRow CW connects to the building loop and delivers 35–120 kW of sensible cooling inside the aisle, with a motorised three-way valve and EC fans that modulate to the actual rack load.
Because there is no compressor in the row, service access is simpler and the unit runs quietly. A 6-row N+1 layout is typical for a 1 MW hall, and each unit can be isolated without affecting its neighbours.
Engineering
Key features
Every item below is verifiable in the datasheet or on the factory acceptance test record.
Data
Specifications
Typical values for the standard configuration. Site-specific schedules are issued with the quotation.
| Sensible capacity | 35 – 120 kW |
|---|---|
| Airflow | 3 000 – 9 000 m³/h |
| Water flow | 1.6 – 5.7 l/s |
| Pressure drop | < 45 kPa |
| Power supply | 380–415 V AC 3Ph |
|---|
| Dimensions | 300 × 1100 × 2000 mm (W×D×H) |
|---|
| Filtration | G4 standard |
|---|
| Protocols | Modbus RTU/TCP, SNMP |
|---|
Deployment
Typical applications
Not on the list? These systems are also deployed in broadcast, rail signalling, laboratory and defence facilities — send us your environment and we will confirm suitability.
Documentation
Datasheets & manuals
The technical datasheet, installation manual and declaration of conformity for this product line are available in the download library. Drawings in DWG and PDF are issued with the quotation.
Related systems
Often specified together
HatchPower HP33 Modular UPS
A hot-swappable modular UPS platform that grows in 50 kVA steps, keeps critical loads on double conversion at 97.6% efficiency and allows zero-downtime maintenance from the front of the cabinet.
HatchPower HP11 Tower UPS
A compact tower UPS for small server rooms, branch offices and telecom cabinets. Online double conversion in a 2U–4U footprint with a maintenance bypass built in.
HatchPower HP33-L Lithium UPS
The HP33 platform paired with LFP battery cabinets and an integrated BMS. Same 97.6% efficiency, but a footprint and weight that fit a retrofit where lead-acid never could.
Next step
Get this system sized for your site.
Share your rack count, density and redundancy target. We reply with a configuration, drawings and a budgetary price.