Containerized Data Centers

CubeDC 40 ft Modular Data Center

Megawatt capacity, assembled from identical blocks.

A 40 ft container with 20–24 racks, aisle containment and up to 1.2 MW of IT capacity — the building block for multi-megawatt container campuses.

1.2 MW Per pod
24 Racks
40 ft ISO footprint
1.25 Design PUE
CubeDC 40 ft Modular Data Center — Up to 1.2 MW per 40 ft pod, two pods per MW block

Overview

Why this system exists

At 40 ft the container stops being an edge device and becomes a building block. Twenty to twenty-four racks, full cold-aisle containment, N+1 in-row cooling and a modular UPS frame deliver up to 1.2 MW per pod; identical pods are then arrayed around a shared plant yard.

Every pod is tested as a unit at the factory, including integrated load bank testing of the UPS and cooling system. On site, pods are placed on pre-cast foundations, connected to the medium-voltage ring and the network spine, and put into service.

Positioning. Up to 1.2 MW per 40 ft pod, two pods per MW block. Configurations are built to order — capacity, redundancy, enclosure rating and monitoring can be specified for your site.

Engineering

Key features

Every item below is verifiable in the datasheet or on the factory acceptance test record.

20–24 racks, up to 1.2 MW IT load
Full cold-aisle containment inside the container
N+1 in-row cooling with adiabatic free cooling
Modular UPS, N+1, with bypass
Integrated BMS/DCIM and CCTV
Stackable two-high option for constrained sites

Data

Specifications

Typical values for the standard configuration. Site-specific schedules are issued with the quotation.

Capacity specifications
IT loadUp to 1.2 MW
Racks20 – 24 × 42U

Deployment

Typical applications

Hyperscale and wholesale colocation campuses Multi-megawatt AI training clusters Military and government facilities Mining and industrial sites with weak grid

Not on the list? These systems are also deployed in broadcast, rail signalling, laboratory and defence facilities — send us your environment and we will confirm suitability.

Documentation

Datasheets & manuals

The technical datasheet, installation manual and declaration of conformity for this product line are available in the download library. Drawings in DWG and PDF are issued with the quotation.

Open download library Ask for a drawing

Next step

Get this system sized for your site.

Share your rack count, density and redundancy target. We reply with a configuration, drawings and a budgetary price.

Request a quote