Containerized Data Centers
CubeDC 40 ft Modular Data Center
Megawatt capacity, assembled from identical blocks.
A 40 ft container with 20–24 racks, aisle containment and up to 1.2 MW of IT capacity — the building block for multi-megawatt container campuses.
Overview
Why this system exists
At 40 ft the container stops being an edge device and becomes a building block. Twenty to twenty-four racks, full cold-aisle containment, N+1 in-row cooling and a modular UPS frame deliver up to 1.2 MW per pod; identical pods are then arrayed around a shared plant yard.
Every pod is tested as a unit at the factory, including integrated load bank testing of the UPS and cooling system. On site, pods are placed on pre-cast foundations, connected to the medium-voltage ring and the network spine, and put into service.
Engineering
Key features
Every item below is verifiable in the datasheet or on the factory acceptance test record.
Data
Specifications
Typical values for the standard configuration. Site-specific schedules are issued with the quotation.
| IT load | Up to 1.2 MW |
|---|---|
| Racks | 20 – 24 × 42U |
| Dimensions | 12 192 × 2 438 × 2 896 mm (ISO 40 ft) |
|---|---|
| Protection | IP55, C5-M option |
| Type | In-row DX + adiabatic free cooling |
|---|
| UPS | 600–1200 kVA modular, N+1 |
|---|---|
| Input | 11 kV / 33 kV via customer MV ring |
| Fire | VESDA, clean agent, emergency lighting |
|---|
| Ambient range | -30 °C to 50 °C |
|---|
| Lead time | 10–14 weeks ex-works |
|---|
Deployment
Typical applications
Not on the list? These systems are also deployed in broadcast, rail signalling, laboratory and defence facilities — send us your environment and we will confirm suitability.
Documentation
Datasheets & manuals
The technical datasheet, installation manual and declaration of conformity for this product line are available in the download library. Drawings in DWG and PDF are issued with the quotation.
Related systems
Often specified together
HatchPower HP33 Modular UPS
A hot-swappable modular UPS platform that grows in 50 kVA steps, keeps critical loads on double conversion at 97.6% efficiency and allows zero-downtime maintenance from the front of the cabinet.
HatchPower HP11 Tower UPS
A compact tower UPS for small server rooms, branch offices and telecom cabinets. Online double conversion in a 2U–4U footprint with a maintenance bypass built in.
HatchPower HP33-L Lithium UPS
The HP33 platform paired with LFP battery cabinets and an integrated BMS. Same 97.6% efficiency, but a footprint and weight that fit a retrofit where lead-acid never could.
Next step
Get this system sized for your site.
Share your rack count, density and redundancy target. We reply with a configuration, drawings and a budgetary price.