Micro-modular Data Centers
MicroCube M1 Single-rack Data Center
One rack. One day. A working data center.
Rack, UPS, cooling, PDU, monitoring and fire suppression integrated into a single 42U closed cabinet. Ships assembled, commissioned in a day, expands rack by rack.
Overview
Why this system exists
Most edge sites fail not because of the technology but because of the integration: a rack here, a split AC there, a UPS in the corner, and nobody accountable when the room overheats on a Sunday. The M1 removes that risk by shipping as a single tested unit.
Inside a sealed 42U cabinet there is a closed-loop cooling unit, a modular UPS, metered PDUs, environmental sensors and a clean-agent fire suppression cylinder. It needs only a power feed and a network drop. Because the cooling loop is closed, the room itself does not need to be air-conditioned.
Engineering
Key features
Every item below is verifiable in the datasheet or on the factory acceptance test record.
Data
Specifications
Typical values for the standard configuration. Site-specific schedules are issued with the quotation.
| IT load | Up to 12 kW |
|---|---|
| Rack space | 42U (standard 19-inch) |
| Type | Closed-loop DX, 3.5–12 kW |
|---|
| UPS | 6–10 kVA modular, 10 min runtime |
|---|---|
| PDU | 2 × metered/switched 32 A |
| Fire suppression | Clean agent, aerosol or Novec option |
|---|
| Sensors | Temperature, humidity, door, smoke, water |
|---|
| Dimensions | 600 × 1200 × 2000 mm |
|---|---|
| Protection | IP21 indoor / IP55 outdoor option |
Deployment
Typical applications
Not on the list? These systems are also deployed in broadcast, rail signalling, laboratory and defence facilities — send us your environment and we will confirm suitability.
Documentation
Datasheets & manuals
The technical datasheet, installation manual and declaration of conformity for this product line are available in the download library. Drawings in DWG and PDF are issued with the quotation.
Related systems
Often specified together
HatchPower HP33 Modular UPS
A hot-swappable modular UPS platform that grows in 50 kVA steps, keeps critical loads on double conversion at 97.6% efficiency and allows zero-downtime maintenance from the front of the cabinet.
HatchPower HP11 Tower UPS
A compact tower UPS for small server rooms, branch offices and telecom cabinets. Online double conversion in a 2U–4U footprint with a maintenance bypass built in.
HatchPower HP33-L Lithium UPS
The HP33 platform paired with LFP battery cabinets and an integrated BMS. Same 97.6% efficiency, but a footprint and weight that fit a retrofit where lead-acid never could.
Next step
Get this system sized for your site.
Share your rack count, density and redundancy target. We reply with a configuration, drawings and a budgetary price.